Energy Efficiency Grade: a+++
Heat Temperature: 50-70°C
Work Environment: Low-temperature Heat Pump
Heat Source: Air-source
Heating Type: Circulating Heat
Application: Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
VS-DCT
Certification
CE, ISO9001, CB, RoHS, SASO, Ec, ETL, cETL, SAA, VDE, En14511-2:2011, ISO14001
Refrigerant
R32
Heater Exchanger
Plate Heater Exchanger
35 Centigrade
a+++
55 Centigrade
a++
Max Heating Outp
70 Centigrade
Heating Curve
Yes
Transport Package
5 Layer Strong Carton
Specification
CE, RoHS, SGS, SASO
Trademark
OEM
Origin
Guangdong
HS Code
841861
Production Capacity
30000PCS/Year

Product Description

Full DC Inverter Evi cooling and heating heat pump of HEEALARX adopts Mistubishi twin rotary inverter type compressor, famous brand plate heater exchanger, panasonic dc inverter fan motor, can operate steadily in -35 centigrade low ambient temperature, for house heating, floor heating, cooling and also hot water for both house and office building. 
Hot Water Heat Pump Connect with Buffer Tank Air Source Heat Pump Water Heater

 

R32  DC INVERTER AIR TO WATER HEAT-PUMP WITH TANK 
Model VS90-DCT  VS160-DCT VS220-DCT 
Power supply   220~240V,50Hz 3/380~415V/50HZ
Hot water(air+20ºC/water15-55ºC) Capacity KW 8.00  13.00  15.0
Heating water capacity KW 2.21  3.61  4.18
Heating(air+20ºC/water55ºC) Capacity KW 9.50  16.20  19.80 
Heating water capacity KW 2,44 4.14  7.67 
Rated current  A 10.69  6.29  5.06 
COP W/W 3.88  3.91  3.92 
Heating(air+7ºC/water35ºC) Capacity KW 9.0 15.0 18.00 
Heating water capacity KW 2.13  3.57  4.35 
Rated current  A 9.35  5.61  6.70 
COP W/W 4.21  4.20  4.13 
Heating(air+2ºC/water35ºC) Capacity KW 8.50  14.5 16.95 
Heating water capacity KW 2.35  4.00  4.72 
Rated current  A 10.32  6.12  7.25 
COP W/W 3.61  3.62  3.59 
Heating(air0ºC/water35ºC) Capacity KW 8.18  14.05  16.52 
Heating water capacity KW 2.46  4.18  5.00 
Rated current  A 10.85  6.35  7.60 
COP W/W 3.32  3.36  3.30 
Heating(air-5ºC/water35ºC) Capacity KW 7.98  13.88  16.12 
Heating water capacity KW 2.64  4.56  5.35 
Rated current  A 11.52  6.93  8.13 
COP W/W 3.02  3.04  3.01 
Heating(air-7ºC/water35ºC) Capacity KW 7.90  13.60  15.82 
Heating water capacity KW 2.73  4.78  5.60 
Rated current  A 11.95  7.35  8.58 
COP W/W 2.89  2.84  2.82 
Heating(air-10ºC/water35ºC) Capacity KW 7.50  12.88  14.98 
Heating water capacity KW 2.84  4.89  5.73 
Rated current  A 12.42  7.40  8.72 
COP W/W 2.64  2.63  2.61 
Heating(air-15/water35ºC) Capacity KW 7.12  11.98  13.88 
Heating water capacity KW 3.08  5.16  6.06 
Rated current  A 13.47  7.84  9.20 
COP W/W 2.31  2.32  2.29 
Heating(air-20/water35ºC) Capacity KW 6.45  10.85  12.58 
Heating water capacity KW 3.19  5.37  6.22 
Rated current  A 13.96  8.16  9.46 
COP W/W 2.01  2.02  2.02 
Heating(air-25/water35ºC) Capacity KW 6.03  9.89  11.61 
Heating water capacity KW 3.48  5.65  6.75 
Rated current  A 15.22  8.58  10.25 
COP W/W 1.73  1.75  1.72 
Heating(air+2ºC/water45ºC) Capacity KW 8.05  13.80  15.48 
Heating water capacity KW 2.75  4.75  5.41 
Rated current  A 12.01  7.25  8.29 
COP W/W 2.92  2.90  2.86 
Heating(air-7ºC/water45ºC) Capacity KW 7.6 13.10  13.85 
Heating water capacity KW 3.06  5.32  5.72 
Rated current  A 13.44 8.12  8.75 
COP W/W 2.48  2.46  2.42 
  Heating(air7ºC/water55ºC) Capacity KW 8.00  14.10  15.15 
Heating water capacity KW 3.05  5.40  5.87 
Rated current  A 13.31  8.25  9.02 
COP W/W 2.62  2.61  2.58 
  Heating(air2ºC/water55ºC) Capacity KW 7.95  13.24  14.05 
Heating water capacity KW 3.34  5.54  5.97 
Rated current  A 14.56  8.45  9.15 
COP W/W 2.38  2.39  2.35 
  Heating(air0ºC/water55ºC) Capacity KW 7.85  12.98  13.57 
Heating water capacity KW 3.39  5.57  5.87 
Rated current  A 14.85  8.46  8.92 
COP W/W 2.31  2.33  2.31 
  Heating(air-5ºC/water55ºC) Capacity KW 7.38  12.26  12.62 
Heating water capacity KW 3.63  6.06  6.31 
Rated current  A 15.92  9.22  9.58 
COP W/W 2.03  2.02  2.00 
Heating(air-10ºC/water55ºC) Capacity KW 6.98  11.42  11.73 
Heating water capacity KW 3.83  6.17  6.40 
Rated current  A 16.75  9.37  9.73 
COP W/W 1.82  1.85  1.83 
Heating(air-15ºC/water55ºC) Capacity KW 6.39  10.53  10.78 
Heating water capacity KW 3.73  6.12  6.34 
Rated current  A 16.33  9.30  9.63 
COP W/W 1.71  1.72  1.70 
Heating(air-20ºC/water55ºC) Capacity KW 5.75  9.54  9.75 
Heating water capacity KW 3.73  6.11  6.41 
Rated current  A 16.36  9.28  9.74 
COP W/W 1.54  1.56  1.52 
Heating(air-25ºC/water55ºC) Capacity KW 5.10  8.36  8.58 
Heating water capacity KW 3.77  6.23  6.54 
Rated current  A 16.52  9.47  9.95 
COP W/W 1.35  1.34  1.31 
Electric heating  KW 3000
current  A 13.6
water pump Input (L/M/H) 55/70/100 135/190/245 135/190/245
Rated current A 0.24/0.30/0.43 0.58/0.82/1.06 0.58/0.82/1.06
Outdoor unit Dimension mm 940*375*800 940*375*1340 940*375*1340
Net/Gross weight kg 32.0  49.0  52.00 
Indoor unit Dimension mm 710*680*1980 710*680*1980 710*680*1980
Net/Gross weight kg 182.0  216.0  232.00 
Outdoor air flow   m3/h 2800 5600 5600.00 
(water)flow rate m3/h 1.6 2.6 3.09 
Design pressure         MPa 4.2/2.1
Refrigerant    R32
Heating water range       ºC 20-55
Cooling water range          ºC 7-35
Ambient temp     ºC -25 ºC - 43ºC -25 ºC - 43ºC -25 ºC - 43ºC
Noise level(1 M) dB(A) 48 48 49

Parts we are using: 

HEEALARX  full inverter evi air water cooling and heating heat pump adopts first class components to ensure that the unit can work in good conditions under low ambient temperature of -35 centigrade with high cop and low noise level. The key components we are using is: Full inverter twin rotary compressor from MITSUBISHI, PANASONIC or GMCC, inverter fan motor,famous brand plate heater exchanger, digital touch controller with wifi. 
Hot Water Heat Pump Connect with Buffer Tank Air Source Heat Pump Water Heater

Wide product range: 


HEEALARX Split type full inverter evi air water cooling and heating heat pump has wide product range capacity from 9kw, 12kw, 15kw, 18.kw and 22kw  can meet different requirement of house heating and cooling both in office and home. 
Hot Water Heat Pump Connect with Buffer Tank Air Source Heat Pump Water Heater

Advantage of HEEALARX  full DC Inverter air to water heat pump evi model Split  type: 

1. Full DC Inverter technology: 
With Panasonic twin rotary compressor and also panasonic brushless inverter fan motor. 
2. Evi Technology: 
Evi technology is adopted so that unit can function well under low ambient temperature of -30 centigrade low

temperature. 

Hot Water Heat Pump Connect with Buffer Tank Air Source Heat Pump Water Heater
3. Wifi Control: 
Wifi control is applicated in our full dc inverter heat pump system. 
4. Warranty: 
3 years on the whole system. 
5. Low noise level 
Special design of air system which can work in super quiet condition with low noise level of 39db. 
6. Modern Touch Controller 
Modern touch controller can intergrate with indoor thermostat. 
Hot Water Heat Pump Connect with Buffer Tank Air Source Heat Pump Water Heater

With 36-months long warranty, HEEALARX SPLIT  DC Inverter Air Source Heat Pumps are designed for sanitory hot water, house heating and cooling with lowest ambient temperature -35ºC. They have the below main features:

* Higher Energy Efficiency
Achieving the ERP A+++ energy class, our DC inverter heat pumps save energy by more than 30% compared with other ordinary air source heat pumps. The maximum COP our DC inverter heat pumps reaches 5.65!


* Low Noise
With Panasonic rotary compressor and DC inverter brushless fans, our DC inverter heat pumps adopt new noise reduction measures so that the sound of the unit is controlled at a satisfactory level.
* Smart WIFI Control
The intelligent controller with RS485 WIFI APP is adopted to realize the linkage control between the heat pump unit and the terminal application end. With the Cascade function, multiple units can be controlled with one panel.
* Wide Voltage Application
The DC Inverter Air Source Heat Pumps operate normally within the voltage range of 150V-260V (1ph) or 330V-450V (3ph) to reduce the impact of voltage instability on the environment.
* Intelligent Defrosting
The smart defrosting technology makes optimal defrosting decisions to minimize energy consumption and improve customer satisfaction.
* Modern touch controller

Modern touch controller can intergrate with indoor thermostat. 
 

CE & A+++ Certified by TUV

 

Whole range of split type full inverter air water house heating heat pump has got CE certified and also got A+++ Certified by TUV. World famous parts such as famous brand plate heater exchanger, wilo inverter water pump and also Panasonic full inverter compressor with evi are adopted to ensure the high quality and good performance of the whole range of split type full inverter air water heat pump with evi.

Hot Water Heat Pump Connect with Buffer Tank Air Source Heat Pump Water HeaterHot Water Heat Pump Connect with Buffer Tank Air Source Heat Pump Water Heater



Brief Company Introduction Regarding Manufacturer: 

Hot Water Heat Pump Connect with Buffer Tank Air Source Heat Pump Water Heater

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now