UK Mcs Certified a+++ High Efficient Monoblock Inverter Air Water House Heating Cooling Hot Water Heat Pump

Product Details
Customization: Available
Energy Efficiency Grade: a+++
Heat Temperature: 50-70°C
Manufacturer/Factory
Diamond Member Since 2024

Suppliers with verified business licenses

  • UK Mcs Certified a+++ High Efficient Monoblock Inverter Air Water House Heating Cooling Hot Water Heat Pump
  • UK Mcs Certified a+++ High Efficient Monoblock Inverter Air Water House Heating Cooling Hot Water Heat Pump
  • UK Mcs Certified a+++ High Efficient Monoblock Inverter Air Water House Heating Cooling Hot Water Heat Pump
  • UK Mcs Certified a+++ High Efficient Monoblock Inverter Air Water House Heating Cooling Hot Water Heat Pump
  • UK Mcs Certified a+++ High Efficient Monoblock Inverter Air Water House Heating Cooling Hot Water Heat Pump
  • UK Mcs Certified a+++ High Efficient Monoblock Inverter Air Water House Heating Cooling Hot Water Heat Pump
Find Similar Products

Basic Info.

Model NO.
VS-DC
Heat Source
Air-source
Heating Type
Circulating Heat
Application
Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification
CE, ISO9001, CB, RoHS, SASO, Ec, ETL, cETL, SAA, VDE, En14511-2:2011, ISO14001
Refrigerant
R410A or R32
Heater Exchanger
Plate Heater Exchanger
35 Centigrade
a+++
55 Centigrade
a++
Max Heating Outp
70 Centigrade
Heating Curve
Yes
Transport Package
5 Layer Strong Carton
Specification
CE, RoHS, SGS, SASO
Trademark
OEM
Origin
Guangdong
HS Code
841861
Production Capacity
30000PCS/Year

Product Description

Full DC Inverter Evi cooling and heating heat pump of HEEALARX adopts Mistubishi twin rotary inverter type compressor, Top brand  plate heater exchanger, dc inverter fan motor, can operate steadily in -35 centigrade low ambient temperature, for house heating, floor heating, cooling and also hot water for both house and office building. 
UK Mcs Certified a+++ High Efficient Monoblock Inverter Air Water House Heating Cooling Hot Water Heat Pump
HEEALARX Monoblock Inverter Air to Water House Heating Heat Pump have both options of 220v and 380v.

Spec for HEEALARX Monoblock Inverter Air Water House Heating Heat Pump 220V

Full Inverter Air Water House Heating Heat Pump Monobloc Type 
Model / VS90-DC1 VS120-DC1 VS150-DC1 VS180-DC1 VS220-DC1
Power Supply / 220-240V~ 50Hz
Heating Condition-Ambient Temp.(DB/WB):7/6ºC,Water Temp.(In/Out):30/35ºC
Heating Capacity Range kW 4.2~9.0 5.5~12.0 6.8~15.0 8.5~18.0 9.5~22.0
Heating Power Input Range kW 0.87~2.14 1.12~2.86 1.42~3.66 1.70~4.23 1.90~5.23
Heating Current Input Range A 3.95~9.73 5.09~13.0 6.45~16.6 7.73~19.2 8.64~23.7
Heating Condition-Ambient Temp.(DB/WB):7/6ºC,Water Temp.(In/Out):40/45ºC
Heating Capacity Range kW 4.5~9.2 5.5~12.0 7.0~15.4 9.2~19.0 10.5~22.0
Heating Power Input Range kW 1.22~2.64 1.37~3.28 1.82~4.35 2.36~5.20 2.53~6.28
Heating Current Input Range A 5.55~12.0 6.23~14.9 8.27~19.8 10.7~23.6 11.5~28.5
Cooling Condition-Ambient Temp.(DB/WB):35/24ºC,Water Temp.(In/Out):12/7ºC
Cooling Capacity Range kW 4.0~7.0 4.5~9.0 5.5~11.5 8.5~14.5 9.0~17.0
Cooling Power Input Range kW 1.18~2.50 1.25~3.22 1.55~4.11 2.43~5.18 2.50~5.67
Heating Current Input Range A 5.36~11.4 5.68~14.6 7.05~18.7 11.0~23.5 11.4~25.8
Cooling Condition-Ambient Temp.(DB/WB):35/24ºC,Water Temp.(In/Out):23/18ºC
Cooling Capacity Range kW 6.0~9.4 6.5~11.5 9.0~15.0 11.0~19.0 13.0~23.0
Cooling Power Input Range kW 1.30~2.35 1.42~2.87 1.96~3.70 2.31~4.63 2.68~5.61
Heating Current Input Range A 5.91~10.7 6.45~13.0 8.91~16.8 10.5~21.0 12.2~25.5
Max. PowerInput kW 3.00  3.70  5.00  6.00  7.20 
Max. Current Input A 13.60  16.80  22.70  27.30  32.70 
ErP Level(35ºC) / A+++ A+++ A+++ A+++ A+++
ErP Level(55ºC) / A++ A++ A++ A++ A++
Water Flow 1.6  2.1  2.6  3.1  3.8 
Refrigerant/Proper Input kg R32/1.40kg R32/1.80kg R32/1.80kg R32/2.05kg R32/2.60kg
Equivalent CO2 TON 0.94 1.21 1.21 1.38 1.75
Sound Pressure At Rated Flow (1m) dB(A) 42 43 45 46 47
Sound Power LevelEN12102 (35ºC) dB(A) 57 59 60 61 62
Cabinet Type / Galvanized sheet
Compressor Brand / Panasoni GMCC Panasoni
Fan Motor Type / DC motor
Operating Ambient Temperature ºC -30~43
Water Connection inch 1 1 1 1 1.2
Net Weight kg 74 78 91 101 124
Gross Weight kg 89 93 107 117 144
Unit Dimensions(L/W/H) mm 1000×440×765 1100×440×945 1005×440×1400
Shipping Dimensions(L/W/H) mm 1178×515×920 1278×515×1100 1182×515×1555
The above data is for reference only;specific data is subject to the product nameplate.


Spec for HEEALARX Monoblock Inverter Air Water House Heating Heat Pump 380v

Full Inverter Air Water House Heating Heat Pump Monobloc Type 
Model / VS90-DC VS120-DC VS150-DC VS180-DC VS220-DC VS250-DC VS300-DC VS340-DC 
Power Supply / 380-415V/3N~ /50Hz
Heating Condition-Ambient Temp.(DB/WB):7/6ºC,Water Temp.(In/Out):30/35ºC
Heating Capacity Range kW 4.2~9.0 5.5~12.0 6.8~15.0 8.5~18.0 9.5~22.0 12.0~25.0 13.0~30.0 15.0~34.0
Heating Power Input Range kW 0.87~2.14 1.12~2.86 1.42~3.66 1.70~4.23 1.90~5.23 2.42~5.95 2.65~7.23 3.06~8.29
Heating Current Input Range A 1.58~3.89 2.04~5.20 2.58~6.65 3.09~7.69 3.45~9.51 4.40~10.8 4.82~13.1 5.56~15.1
Heating Condition-Ambient Temp.(DB/WB):7/6ºC,Water Temp.(In/Out):40/45ºC
Heating Capacity Range kW 4.5~9.2 5.5~12.0 7.0~15.4 9.2~19.0 10.5~22.0 12.5~25.2 13.7~30.0 16.0~33.2
Heating Power Input Range kW 1.22~2.64 1.37~3.28 1.82~4.35 2.36~5.20 2.53~6.28 3.09~7.28 3.47~8.96 4.10~10.2
Heating Current Input Range A 2.22~4.80 2.49~5.96 3.31~7.91 4.29~9.45 4.60~11.4 5.62~13.2 6.31~16.3 7.45~18.5
Cooling Condition-Ambient Temp.(DB/WB):35/24ºC,Water Temp.(In/Out):12/7ºC
Cooling Capacity Range kW 4.0~7.0 4.5~9.0 5.5~11.5 8.5~14.5 9.0~17.0 10.0~19.5 11.0~22.0 12.5~25.0
Cooling Power Input Range kW 1.18~2.50 1.25~3.22 1.55~4.11 2.43~5.18 2.50~5.67 2.78~6.72 3.10~7.72 3.47~8.60
Heating Current Input Range A 2.15~4.55 2.27~5.85 2.82~7.47 4.42~9.42 4.55~10.3 5.05~12.2 5.64~14.0 6.31~15.6
Cooling Condition-Ambient Temp.(DB/WB):35/24ºC,Water Temp.(In/Out):23/18ºC
Cooling Capacity Range kW 6.0~9.4 6.5~11.5 9.0~15.0 11.0~19.0 13.0~23.0 14.0~26.0 14.5~28.5 17.6~32.0
Cooling Power Input Range kW 1.30~2.35 1.42~2.87 1.96~3.70 2.31~4.63 2.68~5.61 2.92~6.34 3.05~7.03 3.67~7.72
Heating Current Input Range A 2.36~4.27 2.58~5.22 3.56~6.73 4.20~8.42 4.87~10.2 5.31~11.5 5.55~12.8 6.67~14.0
Max. PowerInput kW 3.00  3.70  5.00  6.00  7.20  8.50  10.00  12.00 
Max. Current Input A 13.60  16.80  22.70  27.30  32.70  15.50  18.20  21.80 
ErP Level(35ºC) / A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++
ErP Level(55ºC) / A++ A++ A++ A++ A++ A++ A++ A++
Water Flow 1.6  2.1  2.6  3.1  3.8  4.3  5.2  5.8 
Refrigerant/Proper Input kg R32/1.40kg R32/1.80kg R32/1.80kg R32/2.05kg R32/2.60kg R32/3.1kg R32/3.2kg R32/4.0kg
Equivalent CO2 TON 0.94 1.21 1.21 1.38 1.75 2.09 2.09 2.7
Sound Pressure At Rated Flow (1m) dB(A) 42 43 45 46 47 49 51 53
Sound Power LevelEN12102 (35ºC) dB(A) 57 59 60 61 62 64 66 68
Cabinet Type /  
Compressor Brand / Panasonic GMCC Panasonic
Fan Motor Type /  
Operating Ambient Temperature ºC  
Water Connection inch 1 1 1 1 1.2 1.2 1.2 1.5
Net Weight kg 74 78 91 101 124 153 158 185
Gross Weight kg 89 93 107 117 144 175 180 210
Unit Dimensions(L/W/H) mm 1000×440×765 1100×440×945 1005×440×1400 1100×460×1440 1230×545×1525
Shipping Dimensions(L/W/H) mm 1178×515×920 1278×515×1100 1182×515×1555 1278×535×1595 1408×620×1680
The above data is for reference only;specific data is subject to the product nameplate.

Parts we are using: 

HEEALARX  Monobloc full inverter evi air water cooling and heating heat pump adopts first class components to ensure that the unit can work in good conditions under low ambient temperature of -35 centigrade with high cop and low noise level. The key components we are using is: Full inverter twin rotary compressor from MITSUBISHI, PANASONIC or GMCC, inverter fan motor, AL-FA LA AL plate heater exchanger, digital touch controller with wifi. 
UK Mcs Certified a+++ High Efficient Monoblock Inverter Air Water House Heating Cooling Hot Water Heat Pump

Wide product range: 
HEEALARX Monoblock full inverter evi air water cooling and heating heat pump has wide product range capacity from 9kw, 12kw, 15kw, 17.kw, 28kw and also 32kw can meet different requirement of house heating and cooling both in office and home. 
UK Mcs Certified a+++ High Efficient Monoblock Inverter Air Water House Heating Cooling Hot Water Heat Pump
Advantage of HEEALARX  full DC Inverter air to water heat pump evi model monobloc type: 

1. Full DC Inverter technology: 
With Panasonic twin rotary compressor and also panasonic brushless inverter fan motor. 
2. Evi Technology: 
Evi technology is adopted so that unit can function well under low ambient temperature of -30 centigrade low temperature. 
UK Mcs Certified a+++ High Efficient Monoblock Inverter Air Water House Heating Cooling Hot Water Heat Pump3. Wifi Control: 
Wifi control is applicated in our full dc inverter heat pump system. 
4. Warranty: 
3 years on the whole system. 
5. Low noise level 
Special design of air system which can work in super quiet condition with low noise level of 39db. 
6. Modern Touch Controller 
Modern touch controller can intergrate with indoor thermostat. 
UK Mcs Certified a+++ High Efficient Monoblock Inverter Air Water House Heating Cooling Hot Water Heat Pump
With 36-months long warranty, HEEALARX   Monoblock DC Inverter Air Source Heat Pumps are designed for sanitory hot water, house heating and cooling with lowest ambient temperature -35ºC. They have the below main features:

* Higher Energy Efficiency
Achieving the ERP A+++ energy class, our DC inverter heat pumps save energy by more than 30% compared with other ordinary air source heat pumps. The maximum COP our DC inverter heat pumps reaches 5.65!
UK Mcs Certified a+++ High Efficient Monoblock Inverter Air Water House Heating Cooling Hot Water Heat Pump
* Low Noise
With Panasonic rotary compressor and DC inverter brushless fans, our DC inverter heat pumps adopt new noise reduction measures so that the sound of the unit is controlled at a satisfactory level.
* Smart WIFI Control
The intelligent controller with RS485 WIFI APP is adopted to realize the linkage control between the heat pump unit and the terminal application end. With the Cascade function, multiple units can be controlled with one panel.
* Wide Voltage Application
The DC Inverter Air Source Heat Pumps operate normally within the voltage range of 150V-260V (1ph) or 330V-450V (3ph) to reduce the impact of voltage instability on the environment.
* Intelligent Defrosting
The smart defrosting technology makes optimal defrosting decisions to minimize energy consumption and improve customer satisfaction.
* Modern touch controller

Modern touch controller can intergrate with indoor thermostat. 
UK Mcs Certified a+++ High Efficient Monoblock Inverter Air Water House Heating Cooling Hot Water Heat Pump

Installation Diagram for Reference: 
UK Mcs Certified a+++ High Efficient Monoblock Inverter Air Water House Heating Cooling Hot Water Heat Pump
Brief Company Introduction Regarding Manufacturer: 
UK Mcs Certified a+++ High Efficient Monoblock Inverter Air Water House Heating Cooling Hot Water Heat Pump

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier