Customization: | Available |
---|---|
Energy Efficiency Grade: | a+++ |
Heat Temperature: | 50-70°C |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
HEEALARX R290 heating Cooling DHW monoblock air to water heat pump is
an integrated system that provides space heating and cooling as well as domestic hot water, offering a complete, all-year-round solution that can remove the need for traditional gas or oil boilers, or work together with them. It is wide used for commercial, Industrial, residential, etc.
Specification For R290 Propane Inverter Air to Water Heating Cooling Heat Pump
Model | / | VS90-DCR1 | VS120-DCR1 | VS150-DCR1 | VS150-DCR | VS180-DCR1 | VS180-DCR | VS220-DCR1 | VS220-DCR |
Power Supply | / | 220V-240V~/50Hz | 220V-240V~/50Hz | 220V-240V~/50Hz | 380V-400V~/3N/50Hz | 220V-240V~/50Hz | 380V-400V~/3N/50Hz | 220V-240V~/50Hz | 380V-400V~/3N/50Hz |
Heating Condition-Ambient Temp.(DB/WB): 7/6ºC, Water Temp.(In/Out): 30/35ºC | |||||||||
Heating Capacity Range | kW | 2.8~8.0 | 4.0~11.0 | 5.5~14.0 | 5.5~14.0 | 7.0~17.0 | 7.0~17.0 | 8.0~20.0 | 8.0~20.0 |
Heating Power Input Range | kW | 0.56~2.20 | 0.80~3.01 | 1.10~3.84 | 1.10~3.84 | 1.40~4.66 | 1.40~4.66 | 1.60~5.48 | 1.60~5.48 |
COP | kW/kW | 5.00~3.64 | 5.00~3.65 | 5.00~3.65 | 5.00~3.65 | 5.00~3.65 | 5.00~3.65 | 5.00~3.65 | 5.00~3.65 |
Heating Condition-Ambient Temp.(DB/WB): 7/6ºC, Water Temp.(In/Out): 50/55ºC | |||||||||
Heating Capacity Range | kW | 2.6~7.2 | 3.8~10.3 | 5.4~13.3 | 5.4~13.3 | 6.5~16.1 | 6.5~16.1 | 8.3~19.1 | 8.3~19.1 |
Heating Power Input Range | kW | 0.81~2.53 | 1.17~3.55 | 1.70~4.70 | 1.70~4.70 | 2.06~5.75 | 2.06~5.75 | 2.61~6.70 | 2.61~6.70 |
COP | kW/kW | 3.20~2.85 | 3.26~2.90 | 3.18~2.83 | 3.18~2.83 | 3.15~2.80 | 3.15~2.80 | 3.18~2.85 | 3.18~2.85 |
Cooling Condition-Ambient Temp.(DB/WB): 35/24ºC, Water Temp.(In/Out): 12/7ºC | |||||||||
Cooling Capacity Range | kW | 2.0~6.0 | 3.0~8.0 | 4.5~10.5 | 4.5~10.5 | 5.5~13.0 | 5.5~13.0 | 6.0~15.0 | 6.0~15.0 |
Cooling Power Input Range | kW | 0.65~2.73 | 0.97~3.64 | 1.45~4.77 | 1.45~4.77 | 1.77~5.90 | 1.77~5.90 | 1.94~6.82 | 1.94~6.82 |
COP | kW/kW | 3.08~2.20 | 3.09~2.20 | 3.10~2.20 | 3.10~2.20 | 3.10~2.20 | 3.10~2.20 | 3.09~2.20 | 3.09~2.20 |
Hot Water Condition-Ambient Temp.(DB/WB): 20/15ºC, Water Temp.From 15ºC to 55ºC | |||||||||
Hot Water Capacity | kW | 4.5~10.0 | 5.5~14.0 | 6.0~17.0 | 6.0~17.0 | 6.5~20.0 | 6.5~20.0 | 8.0~25.0 | 8.0~25.0 |
Hot Water Power Input | kW | 0.94~2.41 | 1.16~3.37 | 1.28~4.07 | 1.28~4.07 | 1.36~4.88 | 1.36~4.88 | 1.70~6.02 | 1.70~6.02 |
Hot Water Current Input Range | A | 4.3~10.9 | 5.3~15.3 | 5.8~18.5 | 2.3~7.4 | 6.2~22.2 | 2.5~8.9 | 7.7~27.4 | 3.1~10.9 |
Max. Power Input | kW | 3.3 | 4.5 | 5.5 | 5.5 | 6.5 | 6.5 | 7.5 | 7.5 |
Max. Current lnput | A | 15.0 | 20.5 | 25.0 | 10.0 | 29.5 | 11.8 | 34.1 | 13.6 |
ErP Level (35ºC) | / | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ |
ErP Level (55ºC) | / | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ |
Water Flow | m³/h | 1.38 | 1.89 | 2.41 | 2.41 | 2.92 | 2.92 | 3.44 | 3.44 |
Refrigerant | / | R290 | R290 | R290 | R290 | R290 | R290 | R290 | R290 |
Proper Input | kg | 0.50 | 0.70 | 0.85 | 0.85 | 1.00 | 1.00 | 1.20 | 1.20 |
CO2,Equivalent | Tom | 0.0015 | 0.0021 | 0.0026 | 0.0026 | 0.0030 | 0.0030 | 0.0036 | 0.0036 |
Sound Power Level | dB(A) | 57 | 58 | 60 | 60 | 62 | 62 | 64 | 64 |
Operating Ambient Temperature | ºC | -25~43 | |||||||
Max. Water Temperature | ºC | 75 | |||||||
Compressor Brand | / | GMCC | |||||||
Water Side Heat Exchanger | / | Plate type | |||||||
Water Side Heat Exchanger Brand | / | A-L-FA LA-VAL | |||||||
Water Pressure Drop (max) | kPa | 25 | 30 | 26 | 26 | 30 | 30 | 30 | 30 |
Fan Motor Type | / | DC Moter | |||||||
Fan Quantity | / | 1 | 1 | 1 | 1 | 1 | 1 | 2 | 2 |
Water Connection | inch | G1" | G1" | G1" | G1" | G1" | G1" | G1" | G1" |
Circulation Pump | brand | SHIMGE / AWMT | |||||||
Circulation Pump Water Head | m | 12 / 9 / 12.5 | 12 / 9 / 12.5 | 12 / 9 / 12.5 | 12 / 9 / 12.5 | 12 / 9 / 12.5 | 12 / 9 / 12.5 | 12 / 9 / 12.5 | 12 / 9 / 12.5 |
Cabinet Type | / | Galvanized sheet | |||||||
Unit Dimension(L/W/H) | mm | 1167×407×795 | 1167×407×795 | 1280×458×935 | 1280×458×935 | 1280×458×935 | 1280×458×935 | 1250×540×1330 | 1250×540×1330 |
Shipping Dimensions(L/W/H) | mm | 1300×485×930 | 1300×485×930 | 1457×534×1090 | 1457×534×1090 | 1457×534×1090 | 1457×534×1090 | 1380×570×1480 | 1380×570×1480 |
Net/Gross weight | kg | 95/110 | 100/115 | 140/158 | 140/158 | 145/163 | 145/163 | 165/185 | 165/185 |
The above data is for reference only; specific data is subject to the product nameplate. |
Key Advantage of HEEALARX R290 Propane Heat Pump
- Environmental friendly refrigerant R290
- A+++/A+++ high efficiency 75ºC hot water
- Highly (Hitachi) DC inverter compressor
- Built-in water pump-A-L-FA LA-VAL Plate heat exchanger
- Low noise to 38dB
- 4"5"TFT-LCD controller
- Free WIFI intelligent control
- DTU remote tracking module
- S.P.D deforsting in 2 min.
Advantages
HEEALARX R290 heating Cooling DHW monoblock air to water heat pump can meet different requirments of hot water, heating and cooling, has full range functions.